5-22
CP2210 Service Manual
020-100556-04 Rev. 1 (01-2012)
Section 5: Parts and Module Replacement
5.5.23 Lamp Adjust Assembly
UV HAZARD! Wear authorized protective clothing when servicing the main blower
assembly.
The lamp adjust assembly is located directly between the reflector assembly and the lamp blower module, at
the back of the CP2210.
(Estimated Replacement Time: 60 m 10 minute LampLOC
™
alignment)
1. Open the lamp door. Refer to
5.5.10 Lamp Door, on
page 5-9
.
2. Remove the safety shield. Refer to
5.5.12 Safety Shield,
on page 5-10
.
3. Remove the lamp (if installed). Refer to
5.5.15 Lamp
Replacement, on page 5-13
.
4. Remove the top lid. Refer to
5.5.5 Top Lid, on page 5-7
.
5. Remove the cardcage. Refer to
5.6.1 Cardcage Module,
on page 5-36
.
6. Using a 5mm hex key, remove the two screws securing
the lamp adjust. (
Figure 5-31/B
)
7. Using a 3mm hex key, remove the screw securing the
grounding cable. (
Figure 5-31/A
)
8. Disconnect the 11 harnesses from the Intelligent Motor Control Board (IMCB). See
Figure 5-30
.
9. Using the 5mm hex key provided on the inside of the lamp door, unscrew the lamp power supply wire nut
(
Figure 5-31/C
).
Figure 5-31 Unlock Harnesses
Figure 5-30 IMCB
A
Ground Strap
B
Hex Screw (1 of 2)
C
Lamp Power Supply Wire Nut