INSTALLATION AND SETUP
Roadie 25K User’s Manual
2-19
Direct exhaust as necessary to keep ambient air temperature within operating spec
(see Section 6, Specifications). If the projector is used for extended periods,
particularly in a confined space, routing to the outside of the building may be
required. In all cases, maintain at least 600 CFM at the projector’s top exit port:
Table 2.3. Airflow Requirements
Lamp (kW)
Minimum Exhaust Airflow Rate
2.0 600
ft
3
/min.
3.0 600
ft
3
/min.
4.5 600
ft
3
/min.
6.0 600
ft
3
/min.
INSTALLATION:
Follow the installation guidelines provided below, securing all
components in the order that best suits your site and installation requirements.
WARNING
Do not operate the projector without the Christie
Extractor components installed.
1.
INSTALL DUCT ON PROJECTOR:
See
Figure 2.23 below. Align either the 6-
inch or 6-foot duct at the projector’s
top exit port, twisting to secure “flaps”
over projector pins. Confirm that 1)
there are no obstructions or “kinks”
within the ducting, 2) all air intake
areas of the projector are clear and
exposed, and 3) the vane switch at the
exit duct moves freely.
Figure 2.22. Securing Extractor to
Duct
Summary of Contents for Roadie 25K
Page 6: ......
Page 56: ......
Page 153: ...SPECIFICATIONS Roadie 25K User s Manual 6 7 ...
Page 164: ......
Page 165: ...Appendix B Remote Keypad Roadie 25K User s Manual B 1 Figure B 1 Standard Remote Keypad ...
Page 166: ......
Page 168: ...SERIAL COMMUNICATION CABLES C 2 Roadie 25K User s Manual ...
Page 169: ...SERIAL COMMUNICATION CABLES Roadie 25K User s Manual C 3 ...
Page 170: ......
Page 186: ......