SPECIFICATIONS
Roadie 25K User’s Manual
6-5
7 kW 3-Phase Ballast
(38-814001-01)
Nominal Voltage per
φ
• 208 VAC (N. America / Japan)
• 400 VAC (Europe)
Nominal Operating Range
• 200-230 ± 10% (N. America / Japan)
• 380-415 ± 10% (Europe)
Line Frequency
50-60 Hz nominal
Inrush current (max.)
note: excluding lamp
<50
A
Current consumption per phase (max.) @
6.6 kW
• 28 A @ 208 VAC (N. America / Japan)
• 16 A @ 400 VAC (Europe)
Power consumption (max.)
• 14.4 kVA (9.1 kW), all regions
Current rating (continuous) of 3-phase AC
input at breaker
30 A, all regions
Breaker rating
50 A
BALLAST OUTPUT TO PROJECTION HEAD
Operating voltage range
18-46 VDC
Start-up voltage (open current)
125-155 VDC
Operating current range
50-180 A
Ripple
1% max @ 25°C
Control ports
See Control Port and Ballast Ports on
previous page
Ballast
CXL/CDXL Lamps
(kW)
Current Range
(amps)
Lamp Life (warranty hrs.)
CDXL-20 (2.0)
66-88
1200 full / 2400 pro-rated
3 kW Single-
Phase or
7 kW 3-Phase
CXL/CDXL-30 (3.0)
82-120
720 full / 1440 pro-rated
CXL/CDXL-45 (4.5)
112-150
60 full / 900 pro-rated
3-Phase 7 kW
CXL/CDXL-60 (6.0)
126-170
50 full / 500 pro-rated
Notes: 1) Current range shown includes “over-drive”, which is 10% more than the original lamp rating. 2) The 3 kW ballast is
not currently available. 3) Optimized brightness requires CDXL lamp.
Type
Xenolite
®
Stand-by lamp power level for 4.5/6.0
60% of lamp’s maximum current rating
Stand-by lamp power level 2.0/3.0
75% of lamp’s maximum current rating
Motorized adjustment of position
3-axis, 0.25” range for each
10,000 hours
70 dBA maximum
(excluding extractor fan)
• UL 60950 and CAN/CSA C22.2. No. 60950 (2000, 3
rd
edition, bi-national)
• IEC 60950 (1999, 3
rd
edition)
• FCC CFR47, Part 15, Subpart B, Class A — Unintentional Radiation
• CISPR 22: 1997 / EN55022: 1998 — Radio disturbance characteristics, ITE
• CISPR 24 / EN55024:1998 (all parts of immunity characteristics for ITE)
Temperature
10°C to 35°C (50°F to 95°F)
Humidity (non-condensing)
20% to 80%
Altitude
0 – 3000 meters
Tilt, any angle
15° max.
Lamps
'
Reflectors
'
Audible Noise
'
Safety
'
EMC
Emissions
'
EMC
Immunity
'
Operating Environment
'
Summary of Contents for Roadie 25K
Page 6: ......
Page 56: ......
Page 153: ...SPECIFICATIONS Roadie 25K User s Manual 6 7 ...
Page 164: ......
Page 165: ...Appendix B Remote Keypad Roadie 25K User s Manual B 1 Figure B 1 Standard Remote Keypad ...
Page 166: ......
Page 168: ...SERIAL COMMUNICATION CABLES C 2 Roadie 25K User s Manual ...
Page 169: ...SERIAL COMMUNICATION CABLES Roadie 25K User s Manual C 3 ...
Page 170: ......
Page 186: ......