INSTALLATION AND SETUP
2-18
Roadie 25K User’s Manual
1. Check lamp cradle (anode end) location for your lamp
• For 4.5 or 6.0 kW lamps, the
lamp cradle must be as far
forward as possible (factory
default).
• For 2.0 or 3.0 kW lamps, move
the cradle to the rear position, i.e.,
approximately 1” closer to the
reflector.
2. Install Lamp
See 6.4, Replacing the Lamp &
Filter, Steps 7-11. Observe all
warnings, and wear protective
clothing and shielding.
Don’t forget to properly mark the
“Lamp Installed” label on the lamp
door to indicate current lamp size.
Extractor Fan and Duct
For any Roadie 25K with any lamp, install the Christie extractor fan and duct to pull
warm exhaust air from the projector at a minimum rate of 600 CFM. Use either the 6-
in. or the 6-ft. duct in one of the configurations shown below:
Figure 2.21. Extractor Fan Configurations
(MANDATORY SAFETY CABLING NOT SHOWN)
Figure 2.20. Move cradle back for 2.0 or 3.0
Cooling
'