OPERATION
3-74
Roadie 25K User’s Manual
Table 3.6. System Error Codes
Code
Description
GENERAL
12
Software error. Contact dealer/factory.
13
CRC error in flash ROM. Download new software.
14
Engineering-only programming is complete. Call Christie, replace TIPM.
15
Attempting to download s/w code without being in boot mode
16
Invalid interrupt. Power off/on. If persists, contact dealer/factory.
17
User has forced system to stay in boot mode
18
Attempting to program boot mode without jumper
LAMP / BALLAST
20
The lamp is unexpectedly on (likely a ballast and/or wiring problem)
22
One or more high-current lamp cables is not connected
26
Lamp door is open (interlock)
27
Lamp cannot ignite
28
Lamp has turned off unexpectedly
29
Lamp ballast is overheated
2C
Lamp communications fault; ballast is not detected
SENSORS for COOLING
40
Lamp has shut down due to fan failure
46
The red TEC (DMD) has overheated
48
The blue TEC (DMD) has overheated
49
The prism has overheated
4C
Projector has shut down due to critical error
4D
Integrator has overheated
4E
Inadequate lamp air intake rate (interlock)
4F
Inadequate air exhaust rate (interlock)
FANS (note: there are no Fans 1 or 2 in this projector)
53
Fan 3 has failed (side [rear] intake fan)
54
Fan 4 has failed (side [front] intake fan)
55
Fan 5 has failed (lamp exhaust fan)
56
Fan 6 has failed (LAD fan)
57
Fan 7 has failed (card cage fan)
58
Fan 8 has failed (heat exchanger fan — for liquid cooling system)
10-bit IMAGE PROCESSOR (TIPM)
60
Boot code CRC failed
61
Unable to program the DigMux PLD
62
Unable to program the Control PLD
63
Unable to program the Bubks PLD
64
Unrecognized ROM type
65
Write to flash ROM failed
66 General
TIPM
failure
67
Downloaded code will not fit into ROMs
68
Communication error with scaler on TIPM
BUILT-IN KEYPAD or ID EEPROM
70
Unable to access the built-in keypad EEPROM
71
EEPROM on the built-in keypad has re-initialized
IRAM (a.k.a. Panel Driver) or IRAM/TIPM Communications, or EFIB or Modular Formatters
80
Unrecognized IRAM (a.k.a. Panel Driver)
81
Unable to program a device on the IRAM
82
TI flash download fault — critical error
83
TI flash download fault — partial success
84
TI flash download fault — partial success
85 TI
I
2
C fault (write failure)
87
Consecutive RDRAM faults from modular Formatters
90
Red modular Formatter link failure
91
Green modular Formatter link failure
92
Blue modular Formatter link failure
93
Modular Formatter Architecture error
94
Modular Formatter / DMD mismatch
95
Modular Formatter sequence mismatch
96
EFIB not responding to I
2
C messages
BACKPLANE OR OPTIONAL MODULES
A0
Unable to program the optional interface module
A1
Unable to power the optional interface module
A2
Unable to program the Backplane
A3
Unable to program the Warp Module option (
ChristieTWIST
)
Clear system errors with
Exit
Exit
. If necessary, try resetting the projector by powering it off and on
again (cooling if necessary). For detailed information, monitor the RS232 IN port. Contact
dealer/factory if error persists. Codes omitted from this table should not appear in your projector.
Summary of Contents for Roadie 25K
Page 6: ......
Page 56: ......
Page 153: ...SPECIFICATIONS Roadie 25K User s Manual 6 7 ...
Page 164: ......
Page 165: ...Appendix B Remote Keypad Roadie 25K User s Manual B 1 Figure B 1 Standard Remote Keypad ...
Page 166: ......
Page 168: ...SERIAL COMMUNICATION CABLES C 2 Roadie 25K User s Manual ...
Page 169: ...SERIAL COMMUNICATION CABLES Roadie 25K User s Manual C 3 ...
Page 170: ......
Page 186: ......