7 - MAINTENANCE
11. Blow compressed air from the inside of the ele-
ment. Maintain a minimum distance of
3 cm
(
1.2 in
)
between the air nozzle and the inside of the filter
element.
12. Cleaning is complete when no dust comes out of the
filter element any more.
MOLI12LBB0464AB
4
13. With a dry lint free cloth wipe the inside of the filter
housing
(5)
clean. Do not remove the safety filter el-
ement
(4)
.
LEEN12T0883FA
5
14. Insert the main filter element. Make sure that a tight
even seal is made between the filter housing and filter.
15. Secure the filter cover with retaining clips.
7-107