7 - MAINTENANCE
6. After all the coolant drains out, close the radiator drain
cock
(3)
. Do not detach the drain hose.
7. Pour approximately
24 L
(
6.30 US gal
) of clean water
into the reservoir until full.
8. Secure the filler cap
(2)
on the reservoir
(1)
. Attach the
de-aeration valve cap
(4)
if removed.
9. Start the engine and run for at least
30 min
.
NOTE:
Make sure that you activate the heating system (if
equipped) to circulate fluid through the heater core.
10. Remove the filler cap
(2)
.
11. Drain the water from the system.
12. Repeat Steps
5
–
11
for a clean system flush.
13. After the radiator flush has been used, close the radi-
ator drain valve and detach the drain hose.
14. Check the condition of the hoses, connections and the
water pump.
15. Make sure that the external surfaces of the engine and
the radiator are clean.
7-97
Summary of Contents for 580ST
Page 8: ......
Page 24: ...1 GENERAL INFORMATION 1 16 ...
Page 49: ...2 SAFETY INFORMATION Extend telescopic dipper If fitted MOLI12LBB0092AA 24 2 25 ...
Page 101: ...3 CONTROLS AND INSTRUMENTS Setup menu LEIL12TLB00006I 1 3 39 ...
Page 144: ...3 CONTROLS AND INSTRUMENTS 3 82 ...
Page 164: ...4 OPERATING INSTRUCTIONS 4 20 ...
Page 166: ...5 TRANSPORT OPERATIONS RAIL14TLB1181GA 1 5 2 ...
Page 222: ...6 WORKING OPERATIONS 6 44 ...
Page 247: ...7 MAINTENANCE Fuel tank capacity 145 L 38 30 US gal 2WS 124 L 32 76 US gal 4WS 7 25 ...
Page 347: ...7 MAINTENANCE Fuses and relays Powershift cab 2WS MOLI12LBB0491CA 7 7 125 ...
Page 349: ...7 MAINTENANCE Fuses and relays Powershift cab 4WS MOLI12LBB0492CA 8 7 127 ...
Page 390: ...8 TROUBLESHOOTING 8 28 ...
Page 418: ...9 SPECIFICATIONS 4WS LEEN11T0039FA 2 9 28 ...
Page 420: ...9 SPECIFICATIONS 2WS 590ST LEEN11T0041FA 5 4WS 695ST LEEN11T0042FA 6 9 30 ...
Page 433: ......