8 - TROUBLESHOOTING
Electrical System
PROBLEM
POSSIBLE CAUSE
CORRECTION
Loose or oxidised battery
connections.
Check that the battery voltage with
open circuit is at least
12.6 V
.
Clean and tighten the connections.
Sulphated batteries.
Check the electrolyte level and
density.
Battery isolator switch off.
Restore the battery isolator switch.
The electrical system is inoperative.
The main connection fuse of the
machine is blown.
Find the reason of the failure and
replace the connection fuse.
Loose or corroded connections.
Clean and tighten loose connections.
Low battery output voltage.
Check that the battery voltage with
open circuit is at least
12.6 V
. Check
the electrolyte level and density.
Starter motor speed too low, the
engine cranks slowly.
Incorrect viscosity of the engine oil.
Use an oil with correct viscosity for
the temperature conditions.
Transmission gearshift lever
engaged.
Move gearshift lever to neutral.
Loose or corroded connections.
Clean and tighten loose connections.
Starter motor inoperative.
Dead batteries.
Charge or replace the batteries.
Low engine idle speed.
Increase idle speed.
Loose belt.
Check belt tension.
Malfunctioning battery.
Check that the battery voltage with
open circuit is at least
12.6 V
. Check
the electrolyte level and density.
The charge indicator lamp stays on
with the engine running.
Malfunctioning alternator.
Check the alternator and repair, if
necessary.
Loose or corroded battery
connections.
Clean and tighten the connections.
Sulphated batteries.
Check that the battery voltage with
open circuit is at least
12.6 V
. Check
the electrolyte level and density.
Batteries will not charge.
Loose or worn belt.
Check the automatic belt tensioner. If
necessary, replace the belt.
The charge indicator flashes,
indicating excessive charging
voltage.
Malfunctioning alternator.
Check the alternator and repair, if
necessary.
8-25
Summary of Contents for 580ST
Page 8: ......
Page 24: ...1 GENERAL INFORMATION 1 16 ...
Page 49: ...2 SAFETY INFORMATION Extend telescopic dipper If fitted MOLI12LBB0092AA 24 2 25 ...
Page 101: ...3 CONTROLS AND INSTRUMENTS Setup menu LEIL12TLB00006I 1 3 39 ...
Page 144: ...3 CONTROLS AND INSTRUMENTS 3 82 ...
Page 164: ...4 OPERATING INSTRUCTIONS 4 20 ...
Page 166: ...5 TRANSPORT OPERATIONS RAIL14TLB1181GA 1 5 2 ...
Page 222: ...6 WORKING OPERATIONS 6 44 ...
Page 247: ...7 MAINTENANCE Fuel tank capacity 145 L 38 30 US gal 2WS 124 L 32 76 US gal 4WS 7 25 ...
Page 347: ...7 MAINTENANCE Fuses and relays Powershift cab 2WS MOLI12LBB0491CA 7 7 125 ...
Page 349: ...7 MAINTENANCE Fuses and relays Powershift cab 4WS MOLI12LBB0492CA 8 7 127 ...
Page 390: ...8 TROUBLESHOOTING 8 28 ...
Page 418: ...9 SPECIFICATIONS 4WS LEEN11T0039FA 2 9 28 ...
Page 420: ...9 SPECIFICATIONS 2WS 590ST LEEN11T0041FA 5 4WS 695ST LEEN11T0042FA 6 9 30 ...
Page 433: ......