ST-H-AS SENSORTEC

ANALOGUE-ADDRESSABLE

HEAT SENSOR

INSTRUCTION MANUAL

NOV 2006

NITTAN (UK) LTD - BRINGING STYLE INTO FIRE DETECTION SYSTEMS

The new ST-H-AS analogue addressable smoke sensor forms part of a
brand new range of analogue addressable fire detectors from Nittan (UK)
Ltd called SENSORTEC-ANALOGUE.

The ST-H-AS together with the ST-I-AS and ST-P-AS are all low cost,
elegantly designed, low profile fire sensors which are aesthetically
pleasing, thus enabling them to blend unobtrusively into modern work-
ing environments.

The SENSORTEC analogue addressable range all feature the very lat-
est technological advancements increasing reliability and performance
are all compatible with our existing 'AS' protocol and are compatible with
leading analogue addressable panel manufacturers.

SENSORTEC-ANALOGUE...........

From world leaders in 

SENSOR TECHNOLOGY

comes

 

SENSORTEC.........

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание Sensortec ST-H-AS

Страница 1: ... ST I AS and ST P AS are all low cost elegantly designed low profile fire sensors which are aesthetically pleasing thus enabling them to blend unobtrusively into modern work ing environments The SENSORTEC analogue addressable range all feature the very lat est technological advancements increasing reliability and performance are all compatible with our existing AS protocol and are compatible with ...

Страница 2: ...ring current Integral LED fire alarm indicator Remote indicator output on standard models CompatiblewithRB 3 RB 6Bases Compatible with existing AS protocol Flashing LED to indicate sensor is being polled CONTENTS Section 1 Introduction Page 1 Section 2 SensorModels Page 3 Section 3 BaseModels Page 3 Section 4 Installation Page 3 Section 5 Maintenance Cleaning Page 3 Section 6 Specifications Page 4...

Страница 3: ... cover make sure that the led indicator locates properly in the hole in the outer cover before pushing the outer cover home otherwise the led will become damaged Servicing of the system should be carried out in accordance with the requirements of BS 5839 Part 1 Fire Detection and Alarm Systems for Buildings Code of Practice for System Design Installation and Servic ing The maintenance procedures d...

Страница 4: ...mperatureConsiderations Over the range from 10 Deg C to 50 Deg C Humidity Relative Humidity of up to 90 measured at 50 deg C non condensing Section 8 EMC Installation The installation shall be in accordance with the regula tions either of the approval body for an approved system or otherwise to the national code of practice regulations for the installation of the fire alarm system e g BS 5839 part...

Страница 5: ...d 64 8 16 32 4 1 On 2 On 128 Rear of ST H AS Sensor and Address Switch Setting DIL Switch Above switch setting set to address 12 Off Off 64 8 16 32 4 1 On 2 On 128 Above switch setting set to address 26 Off Off 64 8 16 32 4 1 On 2 On 128 Above switch setting set to address 95 Off Off 64 8 16 32 4 1 On 2 On 128 Above switch setting set to address 126 Off Off 64 8 16 32 4 1 2 On 128 OFF RIL REMOTE L...

Страница 6: ...ON MANUAL NOV 2006 Section 9 CONNECTIONS Also suitable for ST I ST P AS smoke sensors Section 10 DIMENSIONS STB 4 base _ 6 5 3 3 6 5 6 3 5 1 1 STB 4 base LED 1 STB 4 base SIG S Low current LED 3mA max STA R1 loop return to control panel 15mm 49mm 104mm www acornfiresecurity com www acornfiresecurity com ...

Страница 7: ...entNo NISM STHA 06 Date NOV 2006 comes SENSORTEC From world leaders in SENSOR TECHNOLOGY ST H AS ANALOGUE ADDRESSABLE HEAT SMOKE SENSOR INSTRUCTION MANUAL www acornfiresecurity com www acornfiresecurity com ...

Отзывы: