15-50
August 2003
Access Navigator - Release 1.8
Diagnostics & Troubleshooting
Send DS1 Payload Pattern with BER Test
Syntax:
send ds1 <n> payload
<
allones
|
allzeros
|
f1in8
|
p2e11
|
p2e15
|
p2e23
|
qrss
>
test
Example:
send ds1 9 payload p2e15 test
For most patterns, the CLI will provide a progress message indicating the success (ok)
or failure of the command followed by the test results, as in the following samples.
Message:
Waiting for pattern sync........ok.
Testing line...
08:15:47 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:48 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:49 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:50 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:51 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:52 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:54 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:55 FBE:0 BE:0 CRC:0 BPV/LCV:0
Field
Description
n
DS1 number, 1 to 32, or a range of numbers such as 2-8.
allones
Send framed all-ones pattern. This can be used as a “keep alive”
signal, idle code, and in measuring the T1 power level.
allzeros
Send framed all-zeros pattern. This can be used to test T1 circuits
for B8ZS clear channel capability and to find equipment
incorrectly set to AMI line code.
Note: When using an all-zeros pattern, a T1 test set (such as a
T-Berd 224 or Sunset T3) must be used to monitor for errors in
the all-zeros pattern from the Access Navigator or looped back
from a far-end network element.
f1in8
Send framed 1-in-8 pattern (also called a 1-and-7 pattern) in
which each payload byte contains the bit pattern 01000000.
(Minimal ones density test for T1 circuits with AMI coding.)
Note
: You must wait 30 seconds after the prompt appears before
doing another test.
p2e11
Send 2
11
–1 pattern with a maximum of 10 consecutive zeros and
11 consecutive ones. (Minimum stress testing.)
p2e15
Send 2
15
–1 pattern with a maximum of 14 consecutive zeros and
15 consecutive ones. (Provides maximum number of consecutive
zeros permissible in framed, non-B8ZS testing.)
p2e23
Send 2
23
–1 pattern with a maximum of 22 consecutive zeros and
23 consecutive ones. (Maximum stress testing.)
qrss
Send QRSS pattern (a modified 2
20
–1) with a maximum of 14
consecutive zeros and 20 consecutive ones. (Common stress test
for T1 data applications.)
Summary of Contents for Access Navigator
Page 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Page 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Page 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Page 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Page 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Page 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Page 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Page 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...