Access Navigator - Release 1.8
August 2003
18-121
CLI Language Reference
CLI Command List
Syntax:
set remote
<
n
>
rs232 baud
<
setting
>
Example:
set remote 9 rs232 baud 57600
Set Remote RS232 Data
Purpose:
Sets Access Bank II remote RS-232 interface data bits and parity.
Security:
Level 2 (operator)
Syntax:
set remote
<
n
>
rs232 data
<
e7
|
o7
|
n8
>
Example:
set remote 9 rs232 data n8
Set Remote RS232 Stop
Purpose:
Sets Access Bank II remote RS-232 interface stop bits.
Security:
Level 2 (operator)
Syntax:
set remote
<
n
>
rs232 stop
<
1
|
2
>
Example:
set remote 9 rs232 stop 1
Field
Description
n
DS1 number, 1 to 32
setting
Baud rate selections are:
1200, 2400, 4800, 9600, 19200, 38400, 57600
Field
Description
n
DS1 number, 1 to 32
e7
7 bit data, even parity
o7
7 bit data, odd parity
n8
8 bit data, no parity
Field
Description
n
DS1 number, 1 to 32.
1
|
2
Number of stop bits, 1 or 2.
Summary of Contents for Access Navigator
Page 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Page 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Page 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Page 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Page 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Page 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Page 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Page 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...