Service Mode > COPIER > ADJUST > DENS
Service Mode > COPIER > ADJUST > DENS
■
DENS
COPIER> ADJUST> DENS
HLMT-PTY
Adj ATR Sensor (Y) dens crrct upr limit
Lv.2 Details
To adjust the upper limit of the target density correction (lower limit of
TD ratio) of the ATR Sensor (Y).
When the value is increased (TD ratio is decreased), fogging/
scattering is alleviated.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
HLMT-PTM
Adj ATR Sensor (M) dens crrct upr limit
Lv.2 Details
To adjust the upper limit of the target density correction (lower limit of
TD ratio) of the ATR Sensor (M).
As the value is incremented by 1, the lower limit of TD ratio is
decreased by 0.5 %.
When the value is increased, fogging/scattering is alleviated.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
COPIER> ADJUST> DENS
HLMT-PTC
Adj ATR Sensor (C) dens crrct upr limit
Lv.2 Details
To adjust the upper limit of the target density correction (lower limit of
TD ratio) of the ATR Sensor (C).
As the value is incremented by 1, the lower limit of TD ratio is
decreased by 0.5 %.
When the value is increased, fogging/scattering is alleviated.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
LLMT-PTY
Adj ATR Sensor (Y)dens crrct lowr limit
Lv.2 Details
To adjust the lower limit of the target density correction (upper limit of
TD ratio) of the ATR Sensor (Y).
As the value is decremented by 1, the lower limit of TD ratio is
increased by 0.5 %.
When the value is decreased, density is increased, but fogging/
scattering occurs.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
Summary of Contents for imageRUNNER ADVANCE C350 series
Page 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER ADVANCE C351 C350 C250 Service Manual Rev 0 0 Series...
Page 24: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name...
Page 490: ...5 5 Adjustment Adjustment Document Exposure System Main Controller Pickup Feed System...
Page 615: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code...
Page 748: ...7 7 7 134 7 134 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101...
Page 771: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD...
Page 1066: ...May 28 2014 PARTS CATALOG imageRUNNER ADVANCE C351 C350 C250 Series...
Page 1082: ...2 6 FIGURE A2 OPTION PARTS CATALOG LIST...
Page 1083: ...2 7 FIGURE 001 ACCESSORIES 120V 230V EUR LTN 5 4 1 2 3 5 6 FR DE GB 7 8 9 10 11 12...
Page 1098: ...2 22 FIGURE 105 INTERNAL COMPONENTS 3 SEE FIGURE 190 SEE FIGURE 460 5 9 7 6 4 1 3 2 8 8 7...
Page 1145: ...2 69 FIGURE B10 READER ADF ASSEMBLY SEE FIGURE D10 SEE FIGURE B11 1 2 3 4 4...