![Canon imageRUNNER ADVANCE C350 series Service Manual Download Page 580](http://html1.mh-extra.com/html/canon/imagerunner-advance-c350-series/imagerunner-advance-c350-series_service-manual_4681960580.webp)
6
6
6-69
6-69
Troubleshooting > Version Upgrade > Version Upgrade via CDS > Error Messages
Troubleshooting > Version Upgrade > Version Upgrade via CDS > Error Messages
No.
Messages
Timing of display
Cause
Remedy
13 Delivery Error
Error Code: [xxx]
UGW linkage (Update
Firmware screen)
eRDS sent an order but Updater failed to
connect to the server.
Conduct a communication test to analyze the cause of the error. After solving the cause, resend
the order from the eRDS.
If it recurs, obtain the log etc. (Refer to
"Information required for Reports" under “Version
Upgrade via CDS”, “Version Upgrade” of Chapter 6 “Troubleshooting” of this manual.) and
contact Support Div. of the sales company.
The delivery server stopped.
Contact the sales company's Support Department. After confirming restoration of the delivery
server, re-execute the job.
If it recurs, obtain the log etc. (Refer to
"Information required for Reports" under “Version
Upgrade via CDS”, “Version Upgrade” of Chapter 6 “Troubleshooting” of this manual.) and
contact Support Div. of the sales company.
The scheduled data and time acquired
from delivery server does not exist.
Do the delivery setting from UGW again.
If it recurs, obtain the log etc. (Refer to
"Information required for Reports" under “Version
Upgrade via CDS”, “Version Upgrade” of Chapter 6 “Troubleshooting” of this manual.) and
contact Support Div. of the sales company.
14 Delivery Error
Delivery Time
Delivery Firmware Label
Delivery Firmware version
Error Code: [ xxx ]
UGW linkage (Update
Firmware screen)
The scheduled date and time acquired
from delivery server was before current
time (15 or more min had passed).
Do the delivery setting from UGW again.
If it recurs, obtain the log etc. (Refer to
"Information required for Reports" under “Version
Upgrade via CDS”, “Version Upgrade” of Chapter 6 “Troubleshooting” of this manual.) and
contact Support Div. of the sales company.
Immediate download
(Update Firmware screen)
At the time of immediate download, turned
OFF and then ON the power of device
main body.
Re-execute the job.
If it recurs, obtain the log etc. (Refer to
"Information required for Reports" under “Version
Upgrade via CDS”, “Version Upgrade” of Chapter 6 “Troubleshooting” of this manual.) and
contact Support Div. of the sales company.
15
Applicable firmware is not registered. On-site (error dialogue)
At the user site, no latest firmware exists. This means the current firmware is the latest, so this error has no impact.
But when the latest firmware to be retrieved must exist e.g. released new firmware information
has been notified, contact Field Support Group in the sales company.
No applicable firmware exists on CDS,
so the service person can't select any
applicable firmware.
Contact the sales company's Support Department.
16 Restart failed.
Turn the main power OFF and ON.
Manual update (error
dialogue)
An error occurred at the time of the device
restart.
After turning OFF and then ON the main power of the device, re-execute the job.
If it recurs, obtain the log etc. (Refer to
"Information required for Reports" under “Version
Upgrade via CDS”, “Version Upgrade” of Chapter 6 “Troubleshooting” of this manual.) and
contact Support Div. of the sales company.
Automatic update (error
dialogue)
An error occurred at the time of the device
restart.
After turning OFF and then ON the main power of the device, re-execute the job.
If it recurs, obtain the log etc. (Refer to
"Information required for Reports" under “Version
Upgrade via CDS”, “Version Upgrade” of Chapter 6 “Troubleshooting” of this manual.) and
contact Support Div. of the sales company.
17
Specify [E-Mail Address] with up to 64
characters.
At the time of periodical
update setting
The specified E-mail address exceeded 64
characters.
Specify E-mail address within 64 characters.
18
The following characters cannot be
used for the [E-Mail Address]:
, : ; “ ( ) [ ] < > \
At the time of periodical
update setting
The E-mail address was including the
characters which could not be used.
Do not specify E-mail address with characters which cannot be used.
19
Specify [Comments] with up to 128
characters.
At the time of periodical
update setting
Comments exceeded 128 characters.
Specify comments within 128 characters.
20
The [Delivery Server URL] is incorrect. In setting with the deliver
server URL.
The specified deliver server URL is wrong. Enter the right URL(https://device.c-cdsknn.net/cds_soap/updaterif)
T-6-21
Summary of Contents for imageRUNNER ADVANCE C350 series
Page 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER ADVANCE C351 C350 C250 Service Manual Rev 0 0 Series...
Page 24: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name...
Page 490: ...5 5 Adjustment Adjustment Document Exposure System Main Controller Pickup Feed System...
Page 615: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code...
Page 748: ...7 7 7 134 7 134 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101...
Page 771: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD...
Page 1066: ...May 28 2014 PARTS CATALOG imageRUNNER ADVANCE C351 C350 C250 Series...
Page 1082: ...2 6 FIGURE A2 OPTION PARTS CATALOG LIST...
Page 1083: ...2 7 FIGURE 001 ACCESSORIES 120V 230V EUR LTN 5 4 1 2 3 5 6 FR DE GB 7 8 9 10 11 12...
Page 1098: ...2 22 FIGURE 105 INTERNAL COMPONENTS 3 SEE FIGURE 190 SEE FIGURE 460 5 9 7 6 4 1 3 2 8 8 7...
Page 1145: ...2 69 FIGURE B10 READER ADF ASSEMBLY SEE FIGURE D10 SEE FIGURE B11 1 2 3 4 4...