2
2
2-215
2-215
Technical Explanation > Embedded RDS > Troubleshooting
Technical Explanation > Embedded RDS > Troubleshooting
3)
When each line is selected, the communication error log detailed screen is displayed as
shown in the figure below. (Example: No. 02)
NOTE:
• A detailed description of the error appears below 'Information'. (Max 128 characters)
• Touch the [OK] button to return to the communication error log list screen.
4)
When a message is displayed, take an appropriate action referring to
"Error code and
strings".
No.2
Symptom: A communication test results NG! even if network setting is set properly.
Cause: The network environment is inappropriate, or RGW-ADR or RGW-PORT settings for
E-RDS have been changed.
Remedy: The following points should be checked.
1)
Check network conditions such as proxy server settings and so on.
2) Check the E-RDS setting values.
•
Check the communication error log from COM-LOG.
• Check whether RGW-ADR or RGW-PORT settings has changed. If RGW-ADR or RGW-
PORT settings has changed, restore initial values. For initial values, see
"Service cautions".
F-2-377
No.3
Symptom: Registration information of the E-RDS machine was deleted from the device
information on Web Portal, and then registered again. After that, if a communication test is
left unperformed, the device setting in the UGW becomes invalid.
Cause: When the registration information of the E-RDS machine is deleted, information
related to E-RDS is also deleted.
Therefore, when 7 days have passed without performing a communication test after
registering the E-RDS machine again, the device setting becomes invalid.
Remedy: Perform a communication test before the device setting becomes invalid.
No.4
Symptom: There was a log, indicating "Network is not ready, try later" in error details of COM-
LOG list.
Cause: A certain problem occurred in networking.
Remedy: Check and take actions mentioned below.
1)
Check networking conditions and connections.
2)
Turn on the power supply of this machine and perform a communication test about 60
seconds later.
No.5
Symptom: "Unknown error" is displayed though a communication test (COM-TEST) has done
successfully.
Cause: It could be a problem at the UGW side or the network load is temporarily faulty.
Remedy: Try again after a period of time. If the same error persists, check the UGW status
with a network and UGW administrator.
No.6
Symptom: Enabling Service Browser (BRWS-ACT) results NG!
Cause: A communication test with UGW has not been performed, or a communication test
result is NG!
Remedy: Perform a communication test, and check that the test with UGW finishes
successfully.
Summary of Contents for imageRUNNER ADVANCE C350 series
Page 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER ADVANCE C351 C350 C250 Service Manual Rev 0 0 Series...
Page 24: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name...
Page 490: ...5 5 Adjustment Adjustment Document Exposure System Main Controller Pickup Feed System...
Page 615: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code...
Page 748: ...7 7 7 134 7 134 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101...
Page 771: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD...
Page 1066: ...May 28 2014 PARTS CATALOG imageRUNNER ADVANCE C351 C350 C250 Series...
Page 1082: ...2 6 FIGURE A2 OPTION PARTS CATALOG LIST...
Page 1083: ...2 7 FIGURE 001 ACCESSORIES 120V 230V EUR LTN 5 4 1 2 3 5 6 FR DE GB 7 8 9 10 11 12...
Page 1098: ...2 22 FIGURE 105 INTERNAL COMPONENTS 3 SEE FIGURE 190 SEE FIGURE 460 5 9 7 6 4 1 3 2 8 8 7...
Page 1145: ...2 69 FIGURE B10 READER ADF ASSEMBLY SEE FIGURE D10 SEE FIGURE B11 1 2 3 4 4...