8
8
8-37
8-37
Service Mode > COPIER > DISPLAY > DENS
Service Mode > COPIER > DISPLAY > DENS
COPIER> DISPLAY> DENS
DENS-S-M
Dspl differ from M patch density tgt VL
Lv.2 Details
To display difference between the M-color target patch density at
ATR control and the patch density detected by the Patch Sensor.
Use case
When analyzing the cause of image failure (fogging, carrier
adherence, low density, etc.)
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
Appropriate target value -350 - 200
DENS-S-C
Dspl differ from C patch density tgt VL
Lv.2 Details
To display difference between the C-color target patch density at ATR
control and the patch density detected by the Patch Sensor.
Use case
When analyzing the cause of image failure (fogging, carrier
adherence, low density, etc.)
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
Appropriate target value -350 - 200
DENS-S-K
Dspl differ from Bk patch density tgt VL
Lv.2 Details
To display difference between the Bk-color target patch density at
ATR control and the patch density detected by the Patch Sensor.
Use case
When analyzing the cause of image failure (fogging, carrier
adherence, low density, etc.)
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
Appropriate target value -350 - 200
D-Y-TRGT
Dspl of ATR ctrl Y patch target density
Lv.2 Details
To display the target density for Y patch image created by ATR
control.
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 65535
Appropriate target value 450 - 640
D-M-TRGT
Dspl of ATR ctrl M patch target density
Lv.2 Details
To display the target density for M patch image created by ATR
control.
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 65535
Appropriate target value 450 - 640
D-C-TRGT
Dspl of ATR ctrl C patch target density
Lv.2 Details
To display the target density for C patch image created by ATR
control.
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 65535
Appropriate target value 450 - 640
COPIER> DISPLAY> DENS
REF-Y
Dspl of Y developer density target value
Lv.2 Details
To display the developer density target value for the ATR Sensor (Y).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
REF-M
Dspl of M developer density target value
Lv.2 Details
To display the developer density target value for the ATR Sensor (M).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
REF-C
Dspl of C developer density target value
Lv.2 Details
To display the developer density target value for the ATR Sensor (C).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
REF-K
Dspl Bk developer density target value
Lv.2 Details
To display the developer density target value for the ATR Sensor (Bk).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
DEV-DC-Y
Dspl of developing DC voltage (Y)
Lv.2 Details
To display the latest Y developing DC voltage Vdc.
Use case
- When image failure occurs due to carrier adherence
- When fogging appears
- When fogging is deteriorated
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1000 to 0
Unit
1 V
Appropriate target value -570 - -450
DEV-DC-M
Dspl of developing DC voltage (M)
Lv.2 Details
To display the latest M developing DC voltage Vdc.
Use case
- When image failure occurs due to carrier adherence
- When fogging appears
- When fogging is deteriorated
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1000 to 0
Unit
1 V
Appropriate target value -570 - -450
Summary of Contents for imageRUNNER ADVANCE C350 series
Page 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER ADVANCE C351 C350 C250 Service Manual Rev 0 0 Series...
Page 24: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name...
Page 490: ...5 5 Adjustment Adjustment Document Exposure System Main Controller Pickup Feed System...
Page 615: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code...
Page 748: ...7 7 7 134 7 134 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101...
Page 771: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD...
Page 1066: ...May 28 2014 PARTS CATALOG imageRUNNER ADVANCE C351 C350 C250 Series...
Page 1082: ...2 6 FIGURE A2 OPTION PARTS CATALOG LIST...
Page 1083: ...2 7 FIGURE 001 ACCESSORIES 120V 230V EUR LTN 5 4 1 2 3 5 6 FR DE GB 7 8 9 10 11 12...
Page 1098: ...2 22 FIGURE 105 INTERNAL COMPONENTS 3 SEE FIGURE 190 SEE FIGURE 460 5 9 7 6 4 1 3 2 8 8 7...
Page 1145: ...2 69 FIGURE B10 READER ADF ASSEMBLY SEE FIGURE D10 SEE FIGURE B11 1 2 3 4 4...