COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-40
<ADJ-XY (image read start position adjustment)>
F00-300-02
<M>
<S>
<R>
<P>
<F>
DISP
ADJUST
FUNC
COUNTER
ADJ-X
OPTION
TEST
xxxx
ADJ-Y
xxxx
ADJ-S
xxxx
ADJ-J
xxxx
ADJ-XY
READY
READY
ADJ-X
*1
Use it to make adjustments so that the image read start position (X direc-
tion, sub scanning direction) matches the reference point on the copyboard
glass.
Fine-adjusts the distance from the original scanner home position sensor to
the read start position.
Unit: Number of steps of the stepping motor.
• Follow the instructions on the next page.
Settings range 0~+400
(–3.9~+3.9mm)
Unit: 0.11 mm (approx.)
ADJ-Y
*1
Use it to make adjustments so that the image read start position (Y direc-
tion, main scanning direction) matches the reference point on the copyboard
glass.
Unit: Pixel
• Follow the instructions on the next page.
Settings range –100~+100
(–2.5~+2.5mm)
Unit: 0.06mm (approx.)
Summary of Contents for CLC 5000
Page 7: ...Main Body Accessory COPYRIGHT 2001 CANON INC 2000 2000 20000 CANON CLC5000 REV 0 JAN 2001 ...
Page 574: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON CLC5000 REV 0 JAN 2001 APPENDIX ...
Page 578: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 A 4 Blank page ...
Page 587: ...Service Mode COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ...
Page 725: ...Error Code COPYRIGHT 2001CANONINC 2000CANONCLC5000REV 0JAN 2001 ...
Page 727: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ii CONTENTS Blank page ...