6.6 Protective Mechanisms
The machine is equipped with the following nine types of protective mechanisms to pre-
vent malfunction of the fixing heater and the oil heater.
6.6.1 Detecting Overheating (software)
The CPU on the DC controller PCB monitors the voltage of the upper main thermistor
(TH1), upper sub thermistor (TH2), lower main thermistor (TH3), and lower sub thermistor
(TH4), and issues the following error codes when detecting an overheating condition:
Thermistor
Detection temperature
Error code
Upper thermistor (TH1)
215ºC
E000-0102
Lower thermistor (TH3)
208ºC
E000-0202
6.6.2 Detecting Overheating (hardware)
When the overheating detection circuit on the DC controller PCB detects any of the fol-
lowing temperature readings, it issues the corresponding error codes; it will then cause the
power OFF signal (PWOFF*) to go ‘0’ so as to turn off the power switch (SW2).
Thermistor
Detection temperature
Error code
Upper main thermistor (TH1)
230ºC
E000-0101
Upper sub thermistor (TH2)
230ºC
E000-0101
Lower main thermistor (TH3)
220ºC
E000-0201
Lower sub thermistor (TH4)
230ºC
E000-0201
Summary of Contents for CLC 5000
Page 7: ...Main Body Accessory COPYRIGHT 2001 CANON INC 2000 2000 20000 CANON CLC5000 REV 0 JAN 2001 ...
Page 574: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON CLC5000 REV 0 JAN 2001 APPENDIX ...
Page 578: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 A 4 Blank page ...
Page 587: ...Service Mode COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ...
Page 725: ...Error Code COPYRIGHT 2001CANONINC 2000CANONCLC5000REV 0JAN 2001 ...
Page 727: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ii CONTENTS Blank page ...