COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-69
<HV-FS (fine-adjustment for pre-fixing high-voltage output ac-
cording to conditions)>
F00-300-29
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks
Same as the reading under ‘DISPLAY > ANALOG’
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks
Same as the reading under ‘DISPLAY > ANALOG’
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks
Same as the reading under ‘DISPLAY > ANALOG’
FS-OFST *
1
Adjusts the transfer high-voltage output.
Settings range –5 ~ +5 (Standard: 0)
Unit: 25 µA
ZONE-A/B/C
Indicates the machine internal humidity absolute value (g) in the three
ranges of A through C.
STMT-MD *
1
Adjust the high-voltage output for size of STMT
Settings range –1 ~ +9 (Standard: 0)
<M>
<S>
<R>
<P>
<F>
ADJUST
DISP
FUNC
COUNTER
OPTION
TEST
HV-FS
1/4
READY
READY
FS-OFST
xxxx
BODY
BODY
BODY
xxx
xxx
xxx
˚C
%
g
ZONE A
ZONE B
ZONE C
0.0g
580g
1800g
580g
1800g
-----g
see
see
see
2/4
3/4
4/4
to
to
to
Summary of Contents for CLC 5000
Page 7: ...Main Body Accessory COPYRIGHT 2001 CANON INC 2000 2000 20000 CANON CLC5000 REV 0 JAN 2001 ...
Page 574: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON CLC5000 REV 0 JAN 2001 APPENDIX ...
Page 578: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 A 4 Blank page ...
Page 587: ...Service Mode COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ...
Page 725: ...Error Code COPYRIGHT 2001CANONINC 2000CANONCLC5000REV 0JAN 2001 ...
Page 727: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ii CONTENTS Blank page ...