COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-41
+
(forward)
Standard white plate
Point of measurement
ADJ-S
*1
Use it to fine-adjust the point at which the standard white plate is measured
for shading correction data.
• Unit: Number of steps of the stepping motor.
• Scratches or dirt, if any, on the standard white plate can cause conspicuous
vertical white lines on copies. If such is noted, shift the point of measure-
ment using ‘ADJ-S’.
F00-300-03
Settings range 0~45
(0~4.8mm)
Unit: 0.11mm (approx.)
ADJ-J
*1
Adjusts the preparatory time for the scanner motor.
Settings range 450~550
Unit: 0.1msec (approx.)
Note 1:
You must enter the appropriate value whenever you have replaced a PCB or ini-
tialized a RAM; record any new values on the service label for this purpose.