CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
5-163
4.1.59 The cassette heater fails to operate.
Environment sensor
1) Is there a significant discrepancy between the temperature/humid-
ity indicated under ‘DISP > ANALOG’ in service mode and the
readings of a thermometer/hygrometer in the room?
NO:
Replace the sensor.
2) Make the following sections in service mode:
DISP > SENSOR. Is the following indication ‘1’?
8 0 2 0 0 9
0 0 1 0 0 0 0 0
3rd bit
NO:
Go to step 4.
Cassette heater (H7, H8)
3) Turn OFF the power switch, and disconnect the connector J6. Set
the meter to the ×1
Ω
Ω
Ω
Ω
Ω
range. Does the index of the meter swing when
the probe of the meter is connected to the terminals of the following
connectors?
Upper Cassette Heater
J6417-1 and J6417-3
Lower Cassette Heater
J6418-1 and J6418-3
NO:
Replace the cassette heater.
Connector
Wiring
4) Are the connection and the wiring between the following connectors
normal?
J61, J62, power-saving switch, J6, J37
Set the meter to the 12VDC range.
NO:
Re-connect them.
YES: Check the wiring from the relay RL1 to the power saving switch
and AC driver PCB; if normal, replace AC driver PCB.
Summary of Contents for CLC 5000
Page 7: ...Main Body Accessory COPYRIGHT 2001 CANON INC 2000 2000 20000 CANON CLC5000 REV 0 JAN 2001 ...
Page 574: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON CLC5000 REV 0 JAN 2001 APPENDIX ...
Page 578: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 A 4 Blank page ...
Page 587: ...Service Mode COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ...
Page 725: ...Error Code COPYRIGHT 2001CANONINC 2000CANONCLC5000REV 0JAN 2001 ...
Page 727: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ii CONTENTS Blank page ...