ERROR CODE
E-19
E350
Cause
ECO-ID PCB (faulty)
Description
•
The ECO-ID PCB is not mounted.
•
The connection between ECO-ID PCB and reader controller PCB is
faulty.
During the power switch has been turned ON, the communication between
ECO-ID PCB and the reader controller is not normal.
E351
Cause
Image processor PCB (faulty)
Description
The communication within the image processor PCB is faulty.
E620
Cause
•
IP-MAIN PCB (faulty)
•
IP-ED PCB (faulty)
Description
The communication between the IP-ED PCB and the IP-MAIN PCB is
interrupted for 5 sec or more.
E700
Cause
•
DC controller PCB (faulty)
•
Reader unit controller PCB (faulty)
•
Power supply PCB (faulty)
Description
The communication between the DC controller PCB and the reader unit
controller PCB is disrupted for 5 sec or more.