COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-87
F00-400-08
■
Entering Backup Data
If you have executed ‘RAM-CLR’ for the DC controller PCB, use this screen to enter the
data recorded on the service label.
SGNL-C/M/Y
Enters the value of the toner density signal when INIT is executed as ATR
control.
REF-C/M/Y
Enters the value of the toner density reference signal when INIT is executed
as ATR control.
SIGG-C/M/Y
Enters the value of the gain for the toner density signal during ATR control
(gain used to set SGNL-C, SGNL-M, and SGNL-Y to 818).
<M>
<S>
<R>
<P>
<F>
FUNC
DISP
ADJUST
COUNTER
OPTION
TEST
REF-M
xxxx
xxxx
REF-Y
SGNL-Y
xxxx
SIGG-Y
SIGG-M
xxxx
xxxx
xxxx
SGNL-M
REF-C
SIGG-C
xxxx
xxxx
xxxx
SGNL-C
DC-CON
READY
3/5
Summary of Contents for CLC 5000
Page 7: ...Main Body Accessory COPYRIGHT 2001 CANON INC 2000 2000 20000 CANON CLC5000 REV 0 JAN 2001 ...
Page 574: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON CLC5000 REV 0 JAN 2001 APPENDIX ...
Page 578: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 A 4 Blank page ...
Page 587: ...Service Mode COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ...
Page 725: ...Error Code COPYRIGHT 2001CANONINC 2000CANONCLC5000REV 0JAN 2001 ...
Page 727: ...COPYRIGHT 2001 CANON INC 2000 CANON CLC5000 REV 0 JAN 2001 ii CONTENTS Blank page ...