Chapter 21: Alarms List
PoE Injector Pin-outs and LEDs – Passive PoE
phn-3963_008v000
Page 21-43
Alarm ID
Type
Description
Severity
Probable Cause
Corrective Action
Notes
4000
Alarm
Card has one or more HW
failures
Critical
One or more HW faults.
Replace card.
4001
Alarm
Card can not function in
2.5Gbps mode.
Warning
The user set an expected card that
does not support 2.5Gbps.
Change the Slot Section to 1Gbps.
4002
Alarm
Card is not functional until
chassis is reset
Warning
Slot is not in 10Gbps mode.
Reset chassis.
5000
Event
User blocked due to
consecutive failure login
Indeterminate
User blocked due to consecutive
failure login
The user should wait few minutes
until it account will be unblock
5001
Alarm
ERPI is either in protection
state or forced protection state
Minor
Either user "force switch"
command or one of the ring links
has failed
Either clear force command or
recover the link
5002
Alarm
More than a single RPL is
configured in a ring
Warning
User configuration
Reconfigure the RPL
5003
Event
LLDP topology change
Warning
New neighbor
None
5004
Event
Security log upload started
Indeterminate
Security log upload started
5005
Event
Security log upload failed
Indeterminate
Security log upload failed
5006
Event
Security log upload succeeded
Indeterminate
Security log upload succeeded
5010
Alarm
System is in sync force mode
state
Warning
5011
Event
The sync-source quality level
was changed
Major
5012
Alarm
System Synchronization
Reference in Holdover Mode
Critical
5013
Event
System Sync reference-to
quality has change changed
Major