Chapter 21: Alarms List
PoE Injector Pin-outs and LEDs – Passive PoE
phn-3963_008v000
Page 21-26
Alarm ID
Type
Description
Severity
Probable Cause
Corrective Action
Notes
1732
Alarm
Power supply cable short
Major
1.
Power is enabled but
consumption reached the
threshold.
2.
Physical short at the ETH
cable.
1.
Check ETH cable and
connectors
2.
Replace RIC (Radio Interface
Card)
3.
Replace RFU
4.
If RFU is connected with an
optical cable, disable power
interface.
1733
Alarm
RFU synthesizer unlocked
Major
At least one of the RFU
synthesizers is unlocked
Replace RFU.
In XPIC mode, replace mate RFU as
well.
1734
Alarm
RFU TX level out of range
Minor
Defective RFU (the RFU cannot
transmit the requested TX power)
Replace RFU.
Intermediate solution - reduce TX
power.
1735
Alarm
RFU TX Mute
Warning
RFU Transmitter muted by user
Unmute the RFU transmitter
1736
Alarm
IDU SW does not support this
type of RFU
Major
IDC SW does not support the RFU
Upgrade IDC SW
1737
Event
Card was extracted from slot
Warning
Card was extracted from slot
NA
1738
Alarm
Card is in Failure state
Major
Card is down as a result of card
failure
1.
Reset Card.
Check if slot was disabled.
1739
Alarm
FPGA Firmware file not found
Critical
There is no FPGA file found on the
Main Board for the card on the slot
NA
1740
Alarm
Download card firmware has
failed
Major
Firmware download was
unsuccessful.
1.
Reset Card.
2.
Download software package.
Try to insert another Card.