Chapter 10: Alarm Management and Troubleshooting
Configuring Voltage Alarm Thresholds and Displaying Voltage
PMs
phn-3963_008v000
Page 10-10
Configuring Voltage Alarm Thresholds and
Displaying Voltage PMs
You can configure undervoltage and overvoltage alarm thresholds and display voltage PMs.
The default thresholds for PTP 850E are:
•
Undervoltage Raise Threshold: 32V
•
Undervoltage Clear Threshold: 34V
•
Overvoltage Raise Threshold: 60V
•
Overvoltage Clear Threshold: 58V
These thresholds determine when the following alarms are raised and cleared:
•
Alarm #32000: Under voltage
•
Alarm #32001: Over voltage
To configure voltage alarm thresholds:
1 Select
Faults > Voltage Alarm Configuration
. The Voltage Alarm Configuration page opens.
Note
You can also open the Voltage Alarm Configuration page by selecting
Platform > PM & Statistics >
Voltage
and clicking
Thresholds
.
Figure 161
Voltage Alarm Configuration Page