Chapter 21: Alarms List
PoE Injector Pin-outs and LEDs – Passive PoE
phn-3963_008v000
Page 21-42
Alarm ID
Type
Description
Severity
Probable Cause
Corrective Action
Notes
2241
Alarm
Multi Carrier ABC Channel Id
Manual Disabled Ch7.
Warning
Admin state for channel is down.
Enable admin state for channel.
2242
Alarm
Multi Carrier ABC Channel Id
Manual Disabled Ch8.
Warning
Admin state for channel is down.
Enable admin state for channel.
2300
Alarm
Protection configuration
mismatch!
Major
The configuration between the
protected devices is not aligned.
Apply copy-to-mate command to
copy the configuration from the
required device to the other one.
All
2301
Event
Copy to mate started
Indeterminate
The copy-to-mate command has
just begun!
This is a notification
All
2302
Event
Copy to mate completed
Indeterminate
The copy-to-mate command was
completed.
This is a notification
All
3000
Event
Chassis was reset
Warning
User issued a command to reset
the chassis.
Wait until the reset cycle is ended
and the system is up and running.
3001
Alarm
Reset chassis to activate front
panel Ethernet ports
Warning
Front panel Ethernet ports cannot
work when slot 12 is configured in
10Gbps mode.
Reset chassis.
3002
Alarm
Front panel Ethernet port
cannot function in current
configured capacity mode
Warning
Front panel Ethernet port cannot
work in a mode other than 1Gbps.
Configure the relevant capacity
mode to 1 Gbps mode.
3003
Alarm
Multi Carrier ABC group is not
functional in current configured
capacity mode
Warning
Multi Carrier ABC group does not
support the configured capacity
mode.
Configure the relevant capacity
mode to 1 Gbps mode.
3004
Alarm
Multi Carrier ABC group is not
functional in current configured
capacity mode until chassis is
reset
Warning
Multi Carrier ABC group capacity
mode is different than the
configured capacity mode.