Chapter 2: Getting Started
Configuring the Radio Parameters
phn-3963_008v000
Page 2-32
Figure 25
Radio Parameters Page
2.
For multi-carrier units, select the carrier in the Radio table and click
Edit
. A separate Radio Parameters page
opens.
i.
In the
TX Frequency (MHz)
field, set the transmission radio frequency in MHz.
ii.
i
In the
RX Frequency (MHz)
field, set the received radio frequency in MHz.
iii.
ii Click
Apply
. The system automatically calculates and displays the frequency separation in the
Frequency Separation (MHz)
field, based on the configured TX and RX frequencies.
iv.
iii Optionally, select
Set also remote unit
to apply the frequency settings to the remote unit as well
as the local unit.
Note:
Release 10.6 does not support the ability to configure the remote frequency
settings.
3.
Set the other radio parameters in the
Configuration parameters
section:
i.
i
To mute the TX output of the radio carrier, select
Mute
in the
TX Mute
field. To unmute the TX
output of the radio carrier, select
Unmute
. To configure a timed mute, select
Mute with Timer
.
If you select
Mute with Timer
, an additional field appears:
Mute timeout (minutes)
. This field defines
a timer for the mute, in minutes (1-1440). When the timer expires, the mute automatically ends. This
provides a fail-safe mechanism for maintenance operations that eliminates the possibility of
accidently leaving the radio muted after the maintenance has been completed. By default, the timer
is 10 minutes.