B-32
AMI Configuration Commands
B.5.3.3
Creating a LECS
This command lets the user create (start) a LECS service. Enter the following
parameters:
localhost::configuration lane lecs>
new <LECS Selector byte (HEX)> [-db <LECS database file>]
[-default <LES atm address>]
LECS Selector byte (HEX)
Indicates the 20th byte of the ATM address of the
host or switch that is to run a LECS service (entered
in hexadecimal format). Use the
conf atmarp get-
nsap
command to display the entire ATM address.
-db <LECS database file>
Indicates the full path to the location and name of the
LECS database file. The default file for a 9A000,
SFCS-200BX, SFCS-200WG, and an SFCS-1000 is
lecs.cfg
. For information about configuring this file,
refer to Chapter 3 of this manual.
-default <LES atm address>
Indicates a default LES address to use in case the
LECS configuration file is inaccessible.
NOTE:
Only one LECS can be created per switch
because the LECS listens for requests on a
well-known address. However, more than
one LEC, BUS, or LES may be created on a
switch.