5-15
Electrical Systems
Section 5
T-top Fuse Block
Main 12 VDC power circuit 5 of 6
provides power to
the fuse block located inside the T-top electronics box.
This circuit is protected by one 60-amp, push button
breaker. The 60-amp breaker is located inside the
control console within seven inches of the house bat-
tery OFF-ON switch.
One Group 27 115 amp hour, deep cycle battery nor-
mally powers this circuit through the house battery
OFF-ON switch.
Ten branch circuits can be connected to the 12 VDC
electrical system at the T-top electronics fuse block.
The T-top electronics fuse block also has ten connec-
tion points for the negative side of the 12 VDC electri-
cal system. Some of the electronics might have been
installed at the factory.
If the 60-amp breaker trips electrically, troubleshoot
the power circuit and its protected devices before you
reset the breaker.
Turning the house battery OFF-ON switch to the
OFF
position at the end of your mission will cut power to the
T-top electronics fuse block.
See
Wire Color Chart
in this section for wire colors.
!
CAUTION
The total combined amperage ratings for all
accessories connected to the T-top fuse block
must not exceed 60 amps. Overloading the T-
top fuse block might cause repeated tripping of
the 60-amp breaker and other electrical
problems.
Summary of Contents for 20 Justice Series
Page 18: ...1 10 Section 1 Safety Deck Occupancy Chart ...
Page 20: ...1 12 Section 1 Safety Warning Label Chart 1 2 3 4 5 7 9 6 8 0 B 7 G A C D E F ...
Page 22: ...1 14 Operator Notes ...
Page 58: ...3 4 Section 3 Fuel Systems Fuel System Diagram RACOR 1 0 2 3 4 5 6 7 8 9 A ...
Page 60: ...3 6 Operator Notes ...
Page 106: ...5 10 Operator Notes ...
Page 137: ...6 21 Operator Notes ...
Page 138: ...6 22 Operator Notes ...