Fig.10-16:
Profibus DP diagnostic overview screen
The detail view provides additional information on each bus device. The detail
view is available for each slave. The detail view is displayed for the bus device
selected (with black borders). There are three ways of opening the detail view:
●
Left-click on the slave desired.
●
Use the arrow keys to select the slaves desired and confirm with <EN‐
TER>.
●
Use the arrow keys to select the slaves desired and confirm with <F9>.
Press <F9> to switch between the overview and detail views.
After you have pressed the key, the detail view will appear on the central and
lower areas of the overview screen. This view provides information on the cur‐
rent state of the bus device, the slave address and the ident number and the
station status. In case of error, the current error number transferred by the con‐
trol and the hexadecimal-encoded channel error text are displayed.
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
Bosch Rexroth AG
203/301
Diagnostics