2-‐5.1.8.3 RMON
Configure RMON Alarm table on this page. The entry index key is
ID.
Web Interface
To display the configure RMON Alarm in the web interface:
1.
Click RMON, Alarm.
2.
Click Add New Entry.
3.
Specify the ID parameters.
4.
Click Apply.
Figure 2-‐5.1.8.3: The RMON Alarm Configuration
Parameter description:
These parameters are displayed on the RMON Alarm Configuration page:
Delete
Check to delete the entry. It will be deleted during the next save.
ID
Indicates the index of the entry. The range is from 1 to 65535.
Interval
Indicates the interval in seconds for sampling and comparing the rising and falling threshold. The
range is from 1 to 2^31-‐1.
Variable
Indicates the particular variable to be sampled, the possible variables are:
InOctets:
The total number of octets received on the interface, including framing characters.
InUcastPkts:
The number of unicast packets delivered to a higher-‐layer protocol.
InNUcastPkts:
The number of broadcast and multicast packets delivered to a higher-‐layer protocol.
InDiscards:
The number of inbound packets that are discarded even if the packets are normal.
InErrors:
Summary of Contents for LPB2910A
Page 7: ...Publication date Sept 2015 Revision A1 ii ...
Page 65: ...Publication date Sept 2015 Revision A1 53 SMTP Enable Select this Group Name in SMTP ...
Page 69: ...Publication date Sept 2015 Revision A1 57 The number of data to be saved in the RMON ...
Page 74: ...Publication date Sept 2015 Revision A1 62 ...
Page 278: ...Publication date Sept 2015 Revision A1 266 Refresh Click to refresh the page ...
Page 365: ...Page 353 Figure 9 21 Restore Configuration option ...