Publication date: Sept, 2015
Revision A1
318
4-‐3 VeriPHY
This section is used for running the VeriPHY Cable Diagnostics. Press to run the diagnostics. This will
take approximately 5 seconds. If all ports are selected, this can take approximately 15 seconds. When
completed, the page refreshes automatically, and you can view the cable diagnostics results in the
cable status table. Note that VeriPHY is only accurate for cables of length 7–140 meters. 10 and 100
Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100
Mbps management port will cause the switch to stop responding until VeriPHY is complete.
Web Interface
To configure a VeriPHY Cable Diagnostics Configuration in the web interface:
1.
Specify the Port that you want to check.
2.
Click Start.
Figure 4-‐3: The VeriPHY
Parameter description:
Port:
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status:
Port: Port number.
Pair: The status of the cable pair.
Length: The length (in meters) of the cable pair.
Summary of Contents for LPB2910A
Page 7: ...Publication date Sept 2015 Revision A1 ii ...
Page 65: ...Publication date Sept 2015 Revision A1 53 SMTP Enable Select this Group Name in SMTP ...
Page 69: ...Publication date Sept 2015 Revision A1 57 The number of data to be saved in the RMON ...
Page 74: ...Publication date Sept 2015 Revision A1 62 ...
Page 278: ...Publication date Sept 2015 Revision A1 266 Refresh Click to refresh the page ...
Page 365: ...Page 353 Figure 9 21 Restore Configuration option ...