2-‐5.1.8.2 History
Configure RMON History table on this page. The entry index key is
ID.
Web Interface
To display the configure RMON History in the web interface:
1.
Click RMON, History.
2.
Click Add New Entry.
3.
Specify the ID parameters.
4.
Click Apply.
Figure 2-‐5.1.8.2: The RMON History Configuration
Parameter description:
These parameters are displayed on the RMON History Configuration page:
Delete
Check to delete the entry. It will be deleted during the next save.
ID
Indicates the index of the entry. The range is from 1 to 65535.
Data Source
Indicates the port ID to monitor. If in a stacking switch, the value must add 1000*(switch ID-‐1). For
example, if the port is switch 3 port 5, the value is 2005.
Interval
Indicates the interval in seconds for sampling the history statistics data. The range is from 1 to
3600, and the default value is 1800 seconds.
Buckets
Indicates the maximum data entries associated this History control entry stored in RMON. The
range is from 1 to 3600, and the default value is 50.
Buckets Granted