87
27
Technical data
Mains connection:
230 V
10 %
50-60 Hz
Current consumption of
appliance tester:
without test socket
with test socket
0.3 A
16.0 A
Maximum current load of
the test socket:
16.0 A
(load type, see following tables)
Maximum pre-fuse:
16.0 A
Protection class:
(as the protective conductor for the test
socket is looped through)
II
Protection category:
IP 40 with the cover being
open
IP 67 with the cover being
closed
Overvoltage category:
II
Contamination level:
2
Touchscreen dimensions:
115 mm x 87 mm
Ambient conditions:
Altitudes of up to 2000 m
above sea level
Temperature range:
Operating temperature
Storage temperature
0.0 °C to 35.0 °C
-20.0 °C to 60.0 °C
Max. relative humidity:
linearly decreasing
non-condensing
80.0 % at 30.0 °C
60.0 % at 40.0 °C
Specified accuracy for
operating temperature
range:
18.0 °C to 28.0 °C
EMC:
DIN EN 61557-16:2015-12,
EN 61326-2-2
Housing:
Carrying case, shock-
resistant and impact-proof
Device regulations:
See chapter 28.
Dimensions
(max.)
:
Height x width x depth
(170 x 410 x 350) mm
Weight:
~6 kg
Tripping type of PRCDs:
PRCD type
Tripping
type
AC
AC
A
half-wave
B
DC
B
DC
2-pin
AC
3-pin
AC
F
half-wave
K
AC
S
AC
S+
AC
Note:
The measuring accuracy is calculated as the sum of a relative part
of the measured value.
This measuring accuracy applies to temperatures from 18 °C to
28 °C and a relative air humidity lower than 80 %.
27.1
Technical data, measuring and device function
DIN EN 61557-16:2015-12:
The tester must allow the measurement of at least the following
parameters:
protective conductor resistance
insulating resistance
protective conductor current
(direct current, differential current or alternative leakage current
method)
contact current
(direct current, differential current or alternative leakage current
method)
The application standards VDE 0701-0702, VDE 0751-1 and
VDE 0544-4 use different terms for the same measuring methods
depending on the properties and intended use of the parts. Thus,
the following terms are used for leakage currents:
device leakage current, earth leakage current, protective
conductor current, contact current, patient leakage current etc.
The measuring data logging works with three measuring ranges
(1:1, 10:1, 100:1). Switch-over of the measuring range occurs
automatically, so that measurement is always carried out in the
most favorable measuring range.
Connections:
separate 4 mm test sockets and IEC connector
4 x USB interface (type A), 1 x USB interface (Mini B)
1 x SD card slot
1 x RJ45
Max. storage capacity of the storage media:
SDHC card max.
32.0 GB
USB stick max.
32.0 GB (FAT32 file system)
Factory settings, system data:
Test time:
5.0 sec.
Safety shutdown:
Time:
30.0 sec.
Transition resistance:
connector
5.0
Ω