61
15.12 ICont weld.
– Contact current of the welding
circuit
VDE 0701-0702
VDE 0751-1 /
EN 62353
VDE 0544-4 /
EN 60974-4
Class
Class
Class
Class
Class
Class
Class
I
II
III
I
II
I
II
-
-
-
-
-
X
X
Explanation
The contact current of the welding circuit is tested to check for
compliance with the rated values of devices according to
VDE 0544-4
.
The test socket is supplied with mains voltage.
Application
Class I, ICont weld.
Direct current measuring method
Connection diagram
VDE 0701-0702
Circuit diagram
VDE 0701-0702
Insert the shock-proof plug of the portable test sample into the
test socket of the appliance tester.
The test sample is supplied with mains voltage.
Use the test probe to scan the poles of the output side.
The current testing current is shown on the display of the
appliance tester.
Class II, ICont weld.
Direct current measuring method
Connection diagram
VDE 0701-0702
Circuit diagram
VDE 0701-0702
Insert the shock-proof plug of the portable test sample into the
test socket of the appliance tester.
The test sample is supplied with mains voltage.
Use the test probe to scan the poles of the output side.
The current testing current is shown on the display of the
appliance tester.
Measurement
Connect the mains plug of the test sample to the test socket of
the appliance tester.
Tap the “
Start
” button.
Move the test probe to both poles of the secondary side one after
the other.
Tap the “
L<->N
” button to reverse the polarity of the
test socket.
Move the test probe to both poles of the secondary side again.
Check the measured values for compliance with the prescribed
limits.
Tap the “
Stop
” button to stop the test.
The “
Test result
” screen opens.