Plexus 9000 Planning and Engineering Guide
Chassis General Description
Section 130-120-100
Issue 4, May 28, 2003
Telica, Inc.
5-11
B
A
B
A
FAN FUSE: 4A
GND
ESD
P462-AA
06-25-01
REAR VIEW
Ground
Lug
Power B
Fan Fuse B
Fan Fuse A
Power A
(ESD)
Electrostatic
Discharge
IOM -17 to 10
Slot 1 I/O 1
Slot 2 I/O 2
Slot 3 I/O 3
Slot 4 I/O 4
[PROT] Slot 5 I/O 5
Slot 6 I/O 6
Slot 7 I/O 7
Slot 8 I/O 8
Slot 21 I/O 17
Slot 11 I/O 9
Slot 20 I/O 16
Slot 19 I/O 15
Slot 18 I/O 14
[PROT] Slot 17 I/O 13
Slot 16 I/O 12
Slot 15 I/O 11
Slot 14 I/O 10
IOM -8 to 1
13 SP/TMG B
9 SP/TMG A
12 SW FAB B
10 SW FAB A
NEG
48Vdc
50 A
RTN
UL 1950
Label
Warning
Label
FCC Rules
Label
Cable
Management
Cover
Read and understand
operator's manual before
using this machine.
Failure to follow operating
instructions could result
in death or serious injury
WARNING
L I S TED
R
C
U S
2000811
ETL LISTED
CONFORMS TO
UL STD 1950
CERTIFIED TO
CAN/CSA STD C22.2 NO.950
Figure 5.1-6. Rear View of 85-3004/3007/3008 Chassis
5.1.3.4 Protection
Slots
All 17 I/O slots may be used for traffic termination. Slot usage is
determined by the chassis part number. For chassis 85-3000 and
Midplane I, the I/O-7 slot is the recommended DS-1 I/O protection slot
and I/O-9 slot is the DS-3 I/O protection slot if line protection is desired.
Refer to
for the illustration of slot protection. All other I/O
slots can be used for any combination of DS-1 or DS-3 modules. The 85-
3000 chassis does not support the octal DS-3 IOM or Network Access
modules.