Front Dual System Processor Timing Module 3
Plexus 9000 Planning and Engineering Guide
Issue 1, April 23, 2004
Section 130-120-220
5-62
Telica,
Inc.
The System Fault Manager receives and records event and fault
notifications related to physical and logical system state changes. It
provides a readable log format to the TL1 agent upon request. It provides
the interface to replication services to allow log replication on protected
SP.
Craft Interfaces
There are two craft interfaces located on the front of the SP module. One
is a DB-9 RS-232 interface and the other is an RJ-45 Ethernet interface.
DB-9 RS-232 Craft Port
A VT-100 terminal or PC running a terminal emulation program can be
connected to the DB-9 connector to configure and retrieve information
using TL1 commands and the element manager.
illustrates a
connection to a terminal/PC or to a modem for connection to a remote
terminal/PC. Refer to
for a description of the connector.
Refer to
for the parameters when using a terminal emulation
program.
There is also a DB-9 craft interface on the rear module. Since this
interface is interconnected to the front interface, a craft connection should
be made to only one connector, not to both.
P156-AA
05-29-02
Telica
Chassis
or
J2
Modem
Remote
Local
Modem
FRONT
SP/
TMG B
SP/
TMG A
SYSTEM
PROCESSOR
TIMING
CRAFT
FLT
ABN
ACT
J1
E
N
E
T
J2
R
S
2
3
2
RST
SYSTEM
PROCESSOR
TIMING
CRAFT
FLT
ABN
ACT
J1
E
N
E
T
J2
R
S
2
3
2
RST
45-2xxx-1-z Cable to Chassis
(Craft Interface) Connector
Craft Modem
Cable 45-2xxx-2-z
xxxx = Feet
z = Cable Revision
NOTE:
Figure 5.4-4. Craft Connection to Terminal/PC or Modem for Remote Connection