Plexus 9000 Planning and Engineering Guide
Front Dual System Processor Timing Module 2
Section 130-120-210
Issue 1, April 23, 2004
Telica, Inc.
5-49
DB-9 RS-232 Craft Port
A VT-100 terminal or PC running a terminal emulation program can be
connected to the DB-9 connector to configure and retrieve information
using TL1 commands and the element manager.
illustrates a
connection to a terminal/PC or to a modem for connection to a remote
terminal/PC. Refer to
for a description of the connector.
Refer to
for the parameters when using a terminal emulation
program.
There is also a DB-9 craft interface on the rear module. Since this
interface is interconnected to the front interface, a craft connection should
be made to only one connector, not to both.
P156-AA
05-29-02
Telica
Chassis
or
J2
Modem
Remote
Local
Modem
FRONT
SP/
TMG B
SP/
TMG A
SYSTEM
PROCESSOR
TIMING
CRAFT
FLT
ABN
ACT
J1
E
N
E
T
J2
R
S
2
3
2
RST
SYSTEM
PROCESSOR
TIMING
CRAFT
FLT
ABN
ACT
J1
E
N
E
T
J2
R
S
2
3
2
RST
45-2xxx-1-z Cable to Chassis
(Craft Interface) Connector
Craft Modem
Cable 45-2xxx-2-z
xxxx = Feet
z = Cable Revision
NOTE:
Figure 5.3-4. Craft Connection to Terminal/PC or Modem for Remote Connection
Table 5.3-F. Craft Terminal Parameters
Parameter Value
Emulation Mode
VT100
Line Wrap
Off
Local Echo
Off
Column Width
80
Rows or Lines
24 to 43
Baud Rate
9600
Data Bits
8
Stop Bits
1
Parity None
Flow Control
Xon/Xoff