System Specifications
Plexus 9000 Installation and Operations Manual
Issue 6, April 25, 2003
Section 130-115-000
4-2
Telica,
Inc.
4.1.2 Dimensions
Table 4-B. Dimensions
MECHANICAL SPECIFICATIONS
Height
22.75”
57.785 cm
Width (with mounting ears)
23.00”
53.975 cm
Depth (cover and tie bars)
18.00”
45.72 cm
Weight (fully loaded)
150 lbs
68
kilograms
9
4.1.3 Environmental
Specifications
represents the environmental specifications for the system and
its plug-in modules.
Table 4-C. Environmental Specifications
Environmental
Conditions
Temp. (°F)
Min/Max
Temp. (°C)
Min/Max
Relative
Humidity
Standard temperature
operation
+41 to +104
+5 to +40
Up to 85%
non-condensing
Standard temperature
short term operation
+23 to +122
-5 to +50
Up to 95%
non-condensing
Standard temperature
storage
-40 to +158
-40 to +70 Up to 95%
non-condensing
Operational altitude
From 200 feet below sea level to 13,000 above
sea level.
Notes
:
1. Temperature ranges refer to the conditions 5 feet above the
bottom of the equipment rack in which the unit is mounted, and
15 inches in front of the unit.
2. Short-term operation refers to a period of not more than 96
consecutive hours, with a total of not more than 15 days per year.
1