Planning for Installation
Plexus 9000 Planning and Engineering Guide
Issue 5, January 24, 2003
Section 130-200-000
6-22 Telica,
Inc.
Table 6.1-Q. Craft Connector
Name Pin
Description
1 DCD
2 RXD
3 TXD
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
P218-AA
07-07-00
1
5
9
6
9 RI
32-A
Table 6.1-R. Required Miscellaneous Cables
Part Number
Description
Number Required
Crossover Ethernet Cable, RJ45 to RJ45
1 if using Craft ENET port
45-1xxx-1-0
Ethernet Cable, RJ45 to RJ45
1 per ENET connector
45-2xxx-1-0
Craft Cable, DB9M to DB9F
1 minimum
45-2xxx-2-0
Craft Modem Cable, DB9M to DB25M
Optional
Note:
XXX is the length of the cable in feet.
A 10/100Base-T Ethernet connector labeled CRAFT ENET is also
available on the front of each SP. Refer to Table 6.1-S for an illustration
of the connector and its pins. These ports were designed as a temporary
connection for provisioning and maintenance. By connecting a PC/laptop,
using a crossover Ethernet cable to this connector, a user can Telnet into
the craft interface for provisioning and monitoring. Because this
connector does not ship with a default IP address, the address and subnet
mask must first be configured using the DB-9 craft port interface. Refer to
for part numbers of cables.