Maintenance and cleaning
78
───
Version: 2.1
eXtended Transport System
Intervals
Operation beyond the permissible environmental conditions and op-
erating states will shorten the intervals. The service life of consum-
ables may be shortened depending on the mechanical dynamics
due to mounted devices and movements. We have provided you
with a list of maintenance work and intervals for the associated com-
ponents below. The intervals are based on the total operating time
of the system and not on the operating time of individual compo-
nents. The data apply to laboratory conditions and a relative humid-
ity of 50% at 25 °C:
Component
Interval
Maintenance
Modules
Coil cores
6 months
Visual inspection of the coil cores for abrasion
Feedback Sensor System
6 months
Visual inspection of the sensor surfaces for abrasion
Machine bed
6 months
Check the fastening of the modules to the machine bed
Guide rails
Straight guide rails
6 months
Check all connections for tightness and wear
Every month
Clean the running surfaces
Recommended cleaner:
Isopropanol
As required
Lubricate the running surfaces
Recommended lubricant:
Vaseline
6 months
Check the fastening of the guide rails to the modules
Curved rails
6 months
Check all connections for tightness and wear
Every month
Clean the running surfaces
Recommended cleaner:
Isopropanol
As required
Lubricate the running surfaces
Recommended lubricant:
Vaseline
6 months
Check the fastening of the curved rails to the modules
Mover gate
6 months
Check the mover gate for wear and break outs
Every month
Clean the running surfaces
Recommended cleaner:
Isopropanol
As required
Lubricate the running surfaces
Recommended lubricant:
Vaseline
6 months
Check the fastening of the lock
6 months
and whenever it is opened
Check that the lock is seated correctly
Mover
Guide rollers
3 months
or when the expected service life
has been reached
Check the guide rollers for wear and breakouts
Magnetic plates
6 months
Check the magnetic plates for abrasion and damage
Encoder flag
6 months
Check whether the encoder flag is secure
6 months
Check that the encoder flag is not rubbing against the module sen-
sors
Carbon fiber brush
6 months
Check whether the brush exists
6 months
Check that the brush is firmly seated
6 months
Check whether the distance between the brush and the guide rail is
less than 1 mm.