Technical data
Version: 2.1
───
21
eXtended Transport System
Data for operation and
environment
Beckhoff products are designed for operation under certain environ-
mental conditions, which vary depending on the product. The follow-
ing specifications must be observed for operation and environment
in order to achieve the optimum service life of the products.
Operate the XTS only under the specified environmental con-
ditions
Operate the Beckhoff XTS only in accordance with the specifica-
tions for operation and the environment listed in this chapter. This
ensures a long service life and proper operation.
The service life of the system may be shortened at temperatures
above 40 °C. Speak to our Applications Department in case of de-
viating environmental conditions and operating states of your ma-
chine or plant.
Environmental requirements
Climate category
2K3 according to EN 60721
Ambient temperature (operation)
+5 to +40 °C
Ambient temperature (transport and storage)
-25 to +85 °C
Permissible air humidity (operation)
15% to 95% relative humidity, no condensation
Contamination level
EN 60204 / EN 50178 Level 2
Ventilation
via convection
Specifications for intended use
Power derating (currents and torques)
For site altitudes higher than 1000 to 2500 m above sea level and 40 °C:
1.5 % per 100 m
Insulation material class
F according to IEC 60085 (UL1446 class F)
Protection class
IP65
Vibration resistance
conforms to EN 60068-2-6
Shock resistance
conforms to EN 60068-2-27
EMC requirements
conforms to EN61000-6-2 / EN61000-6-4
Approvals
CE, cURus, EAC