Mechanical installation
44
───
Version: 2.1
eXtended Transport System
Maintenance concept
Fast reaction in case of a module failure
You have the option to assemble the XTS in such a way that you
can replace individual supply segments in case of a failure. As a
result you do not have to dismantle the entire XTS system and you
can minimize the downtime and maintenance work.
With locating pins
BECKHOFF
insert this
side first
1
2
4
3
With the standard assembly, all guide rails are connected with the
locating pins 1 and all individual modules with locating pins 2. The
goal of this maintenance concept is to generate individual ex-
changeable supply segments between supply modules 4 and mod-
ules without supply 3 so that each supply segment can be removed
individually from the complete system.
Without locating pins
BECKHOFF
insert this
side first
1
2
4
3
You have the option to generate exchangeable module segments by
not using the locating pins 1 and 2. As the locating pins 2 are miss-
ing on the cable side (front side) of the supply module 4, an individ-
ual supply segment can be completely removed from the XTS sys-
tem.