International and national certifications
360
X90 mobile system User's manual V 1.20 - Translation of the original manual
7.3.2 Emission requirements
Testing
Test method per
Limit values per
UN/ECE-R10 - Vehicle approval (EMC)
EN 13309 - Construction machinery
Conducted transient emissions
ISO 7637-2
ISO 13766 - Earth-moving machinery
UN/ECE-R10 - Vehicle approval (EMC)
EN 13309 - Construction machinery
ISO 13766 - Earth-moving machinery
EN ISO 14982 - Agricultural and forestry machinery
Radiated emissions
EN 55025 (CISPR 25)
ISO 15003 - Agriculture engineering
Conducted transient emissions
Testing performed per
ISO 7637-2
Limit values per
UN/ECE-R10 / EN 13309 / ISO 13766
(12 V / 24 V system)
Power on (switched fast/slow)
Power off (switched fast/slow)
Positive pulse amplitude
Max. +75 V
Negative pulse amplitude
Max. -100 V
Radiated emissions
Testing performed per
EN 55025 (CISPR 25)
Limit values per
UN/ECE-R10 / EN 13309 / ISO 13766 / EN ISO 14982 / ISO 15003
Electric field / Measured from 1 m
30 MHz to 75 MHz
52 to 42 dB (µV/m)
Mean
62 to 52 dB (μV/m)
Quasi-peak value
Electric field / Measured from 1 m
75 MHz to 400 MHz
42 to 53 dB (µV/m)
Mean
52 to 63 dB (µV/m)
Quasi-peak value
Electric field / Measured from 1 m
400 MHz to 1 GHz
53 dB (µV/m)
Mean
63 dB (µV/m)
Quasi-peak value