X90 mobile modules
X90 mobile system User's manual V 1.20 - Translation of the original manual
107
Multifunction output MF-PWM, PWM output, source circuit
10 kΩ
12/24 V
Status
Current
Relay active
PWM
GND
ECU
Vcc
Supply voltage Vs1
10 A slow-blow
Multifunction output MF-PWM, PWM output, sink circuit
12/24 V
(output power supply)
Digital output
10 kΩ
PWM
GND
Status
Current
Status
Current
Digital output:
Load output power supply (permanently on)
PWM:
- Active freewheeling low-side output (load connected to output power supply)
Relay active
ECU
Vcc
Supply voltage Vs1
10 A slow-blow