5.4.1.5.10.14 FrequencyBandLowerFrequencyRead
Name:
FrequencyBand01LowerFrequencyRead to FrequencyBand32LowerFrequencyRead
Registers for reading the minimum frequency of individual frequency bands.
The minimum frequency is specified in 1/4 Hz.
Data type
Values
UINT
1 to 40,000
5.4.1.5.10.15 FrequencyBandUpperFrequency
Name:
FrequencyBand01UpperFrequency to FrequencyBand32UpperFrequency
Maximum frequency for calculating the frequency band if it is not speed-dependent.
The maximum frequency must be specified in 1/4 Hz.
Data type
Values
Information
UINT
1 to 40,000
Bus controller default setting: 0
5.4.1.5.10.16 FrequencyBandUpperFrequencyRead
Name:
FrequencyBand01UpperFrequencyRead to FrequencyBand32UpperFrequencyRead
Registers for reading the maximum frequency of individual frequency bands.
The maximum frequency is specified in 1/4 Hz.
Data type
Values
UINT
1 to 40,000