X90 mobile modules
310
X90 mobile system User's manual V 1.20 - Translation of the original manual
5.6.1.7.2 Output circuit diagram
PWM output, source circuit
10 kΩ
12/24V
Status
Current
Relay active
PWM
GND
ECU
Vcc
Supply voltage Vs1
10 A slow-blow
PWM output, sink circuit
12/24 V
(output power supply)
Digital output
10 kΩ
PWM
GND
Status
Current
Status
Current
Digital output:
Load output power supply (permanently on)
PWM:
- Active freewheeling low-side output (load connected to output power supply)
Relay active
ECU
Vcc
Supply voltage Vs1
10 A slow-blow
Note that in the event of power failure or if the enable relay is cut off, then the power supply for the actuator is
also cut off. This is because it will otherwise continue to operate and the module is supplied with power via the
freewheeling diode, which can result in damage. It is therefore recommended to provide power to low-side outputs
via a high-side output of the same option board.