X90 mobile modules
146
X90 mobile system User's manual V 1.20 - Translation of the original manual
5.3.1.7.6 Analog outputs
The module is equipped with 8 analog outputs for 1-wire connections.
5.3.1.7.6.1 Output values of the analog outputs
Name:
AnalogOutput01 to AnalogOutput08
These registers provide the standardized output values. Depending on the configuration selected (
see "Physical
configuration" on page 144
), the range of values can be adapted to the requirements of the application. Once a
permissible value is transferred, the module outputs the corresponding current or voltage.
Data type
Values
Information
INT
0 to 32767
Current or voltage value (0 to 10 V or 0 to 20 mA)
Note:
The analog output can only be controlled if it is switched on using register OutputEnable01 to Out-
putEnable08.
5.3.1.7.6.2 Switching the output channels on/off
Name:
OutputEnable01 to OutputEnable08
Byte "OutputEnable" is only needed for the channels that are configured as outputs.
The individual bits are used to switch the respective channels on/off.
Data type
Values
USINT
See the bit structure.
Bit structure:
Bit
Description
Value
Information
0
Output disabled
0
OutputEnable01
1
Output enabled
...
...
...
...
0
Output disabled
7
OutputEnable08
1