X90 mobile modules
142
X90 mobile system User's manual V 1.20 - Translation of the original manual
5.3.1.6.1 Input circuit diagram
Digital input, negative switching
A/D converter
or
Comparator
Source configuration
6.9 / 10 / 22 kΩ
Supply voltage Vb2
Digital input
KL30
12/24 V
ECU
Sensor input (negative switching)
GND
5 A slow-blow
Digital input, positive switching
A/D converter
or
Comparator
Sink configuration
6.9 / 10 / 22 kΩ
Digital input
12/24 V
ECU
Sensor input (positive switching)
GND
KL30
5 A slow-blow
5.3.1.6.2 Output circuit diagram
Analog voltage output
Analog output
ECU
Analog GND
>1 kΩ
Voltage source
0.1 to 10 V