X90 mobile modules
104
X90 mobile system User's manual V 1.20 - Translation of the original manual
Multifunction analog input MF-AI, voltage input
A/D converter
Analog input
ECU
Analog GND
6.9 / 24.9 kΩ
Voltage source
0 to 10/32 V
Multifunction analog input MF-AI, current input
A/D converter
Analog input
ECU
Analog GND
Current source
0 to 20 mA
PTC
Shunt
Multifunction output MF-DO, digital input, negative switching
10 kΩ
12/24 V
Relay active
Source configuration
Digital input
GND
Status
Current
ECU
Vcc
Supply voltage Vs1
10 A slow-blow